  • 400ma diagnostic x ray systems device MSLCX25 400ma diagnostic x ray systems device MSLCX25

400ma diagnostic x ray systems device MSLCX25

Quick Overview

Brand:MedsinglongService:Medsinglong after-sales support.Contact us: Cindy@medmsl.com

Availability: In stock

$9,999.00

Details

1.single diagnostic table and x-ray rubes 
2.x-ray tube run safely long time 
3.Bigger scope of rotation diagnostic table 
4.CE 

 

400ma xray systems & device-MSLCX25

 xray device

xray systems

 

 

Features

 

1)  Equipped with single diagnostic table and x-ray rubes, single direct bridge full-wave commutation, tube voltage is 125kV, tube current is 400mA.

2)  X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

3)  Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation –proof, ensure operate and the tested.

4)  Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.

5)  Applied in all kinds of hospital for radiography such as general body,beam filtration,and chest.

 

Technical parameter

 

 

 

Department

Technology parameters

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube current

0.3-5mA continuous current

Tube voltage

45-110KV continuous voltage

Radiography

Tube current

50-400mA shift

Tube voltage

45-125KV continuous voltage

Exposure time

0.03-5s,23 shift

Power

Voltage

380V±10%

Frequency

50Hz±1Hz

Capacity

≥30KVA

Inner resistance

≤0.3Ω

X-ray assembly

Type of x-ray

XD51-20.40/125

Focus

1×1.2×2 double focal

Rated rotate speed of anode

2800r/min

CDG Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

Across

±120mm

Mobile beam filtration grid

Grid density

28L/cm

Grid ratio

8:01

Focusing distance

100cm

Scope of moving

≥600mm

Radiography item

5”×7”,8”×10”,10”×12”,11”×14”,

12”×15”,14”×14”,14”×17”

Distance from surface to film

75mm

Height of bed

700mm

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

Bulb tube

Rotate the cross arm±180,ascend $ descend 1100mm

 

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

The minimum distance from focal spot

380mm

Radiography item

8”×10” 10”×12” 11”×14”12”×15”

14”×14” 14”×17”

Fixed beam filtration role

Grid density

40L/cm

Grid radio

10:01

Focal distance

180cm