Accurate vet patient monitor MSLMP06

Accurate vet patient monitor MSLMP06
$9,999.00

Availability: In stock

Model No:MSLMP06 Brand:Medsinglong Service:Medsinglong after-sales support. Contact us: Cindy@medmsl.com Keywords:vet patient monitor
OR
Description

Details

Display screen vet patient monitor for sale MSLMP06

Professional vet patient monitor for sale MSLMP06

12.1" color TFT screen

Multi‐channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti‐defibrillation design
NIBP over pressure protection
Plug‐in rechargeable battery, AC/DC available.
Supporting wire or wireless network.

portable vet patient monitor for sale MSLMP06

use vet patient monitor for sale MSLMP06

MSL vet patient monitor for sale MSLMP06 Technical Specifications

ECG
Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V
Wavef orm 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Wave form 1 ch
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
HR and Alarm Range Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ±1% or±1bpm, which is greater
Resolution 1 bpm
Sensitivity > 200 (uVp-p)
Differential Input Impedance > 5 MΩ
CMRR Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range ±8 m V ( Vp-p )
Bandwidth Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Calibration Signal 1 (mVp-p), Accuracy:5%
ST Segment Monitoring Range Measure and Alarm -2.0 ~ 2.0 mV
ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
PNP, PNC,Alarm Available,Review Available
Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance > 2.5 MΩ
Measuring Impedance Range 0.3~3 Ω
Base line Impedance Range 200~4 KΩ
Bandwidth 0.1~2.5Hz
Resp. Rate Measuring and Alarm Range
Adult 0 ~ 120 Brpm
Neo/Ped 0 ~ 150 Brpm
Resolution 1 Brpm
Accuracy ±2 Brpm
Apnea Alarm 10 ~ 40 S
MSL vet patient monitor for sale MSLMP06
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution 1mmHg
Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization intervalabout 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate Measuring and Alarm Range 20~300 bpm
Resolution 1bpm
Accuracy ±3bpm
TEMP
Channel 2
Measuring and Alarm Range 0 ~ 50 ℃
Resolution 0.1 ℃
Accuracy ±0.2 ℃
Actualization intervalabout 1 Sec.
Average Time Constant < 10 Sec.
IBP
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP-10 ~ 40 mmHg
P1 / P2-10 ~ 300 mmHg
Press Sensor Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy ±2% or 1mmHg which is greater
Actualization interval about 1 secretary
Best vet patient monitor for sale MSLMP06
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
Cheap vet patient monitor for sale MSLMP06

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *
PDF Download
test content
FAQ

1. How long is the warranty?
2 years.

2. Can I choose other language?
It depends. Most machines have multiple language.

3. What certificate do you have?
Generally, most machine have CE, ISO, FSC. Some have FDA.

4. How long is the delivery?
About 4 days

5. How can I pay?
Paypal, Western Union, T/T, L/C, Trade Assurance, Money Gram etc. are accepted.

1. Can the medical incinerator burn dead body?
No, It is a non-hazardous treatment device commonly used in medical waste, such as blood cotton, needles, and disposable syringes

2. Can a medical incinerator use gasoline?
No, only diesel or natural gas liquefied gas.

What type of gas does the body cabinet compressor use?
Secop's compressors use R134a refrigerant. The refrigerant is universal and easy to buy. The refrigerant used in domestic compressors is r12, which is easy to purchase in the domestic market.

4. Does the body cabinet need to be installed before using?
No need to install. Plug it in directly. But if it is shipped by air, the refrigerant needs to be pumped out and refilled before use.

5. Is there an analysis segment for the human body analyzers MSLCA01, MSLCA02, MSLCA03, MSLCA04?
The MSLCA01 Body Analyzer does not have this function, MSLCA02, MSLCA03, MSLCA04 have the function of segmental fat, segmental moisture analysis, edema coefficient analysis, detailed body water analysis, intracellular water, extracellular water, and body water status.

6. Can the body analyzer be OEM?
It is possible when it reaches a certain amount. At present, we are all shipping from neutral machines.

7. What languages ​​does the body analyzer support?
MSLCA01 supports French, Italian, German, Portuguese, Spanish, Russian, English, Simplified Chinese, and Traditional Chinese. MSLCA02, MSLCA03, MSLCA04 support German, English, Simplified Chinese, Traditional Chinese. Lhe language needs to be confirmed in advance.

8. Can an endoscope camera connect to a monitor?
Yes, you can choose different size: 15 inches, 21 inches, 24 inches and 26 inches.

9. How often does one need to change oil in vacuum pump?

The vacuum pump oil is changed once every six months, and the pump oil is changed for 200 hours according to the frequency of use. If the catch water is overloaded, there will be a small amount of water to the vacuum pump part and then the cold trap, so the pump oil must be changed.

10. How high the degrees can the MSLFV02 refrigerator do?
Cold trap -40 degrees, plate temperature -35 degrees. This model is used for food and vegetables.

11. Can endoscopes add an extra camera?
Yes, we generally do not advise customers to purchase two cameras because the camera is the most important component of the entire device, so the price is relatively high. Of course, if customers want to buy, it is ok.