Sevoflurane Gas Anesthesia machine - MSLGA02

Sevoflurane Gas Anesthesia machine - MSLGA02
$9,999.00

Availability: In stock

Model No:MSLGA02 Brand:Medsinglong Service:Medsinglong after-sales support. Contact us: Cindy@medmsl.com Keywords:sevoflurane anesthesia
OR
Description

Details

Sevoflurane Anesthesia or Other Gas Anesthesia machine - MSLGA02
1. Medical anesthesia machine

2. Vertical anesthesia equipment

3. Mobile anesthesia machine

4. Anesthesia gas machine

mobile anaesthetic machine ce approved
1. Gas source:O2: 0.27~0.55MPa,N2O: 0.27~0.55MPa
2. bellows for adults and children

Sevoflurane Anesthesia or Other Gas Anesthesia machine - MSLGA02

MSLGA02 anaesthetic machine:5.7inc LCD ventilator,real-time display of pressure/time and flow-speed/time waves, incorporation

Sevoflurane Anesthesia machine - MSLGA02

Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions. Both outstanding and inexpensive, it has the best cost performance that can satisfy any customer.

1, The Ventilator adopts microcomputer control with high-definition 5.7” LCD display,integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.

2, The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.

3, Reliable pneumatic transmission system.

4, Economic and proper configuration of technologies, optional as required by the Customer.

5, Modularized design and upgrading. Upgrading is available as required by the Customer.

Main body High-strength engineering plastic rack, light,
beautiful and corrosion resistant
Scope of application adult, child
Gas source O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
Flow meter O2: 0.1~10L/min N2O: 0.1~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply 25~75L/min
Low oxygen pressure alarm(Oxygen Alarm) There will be sound alarm when the oxygen
pressure < 0.2MPa
Vaporizer(Vaporizer Definition and Vaporizer Construction) it has the function of automatic compensation
based on pressure, temperature, and flow rate.
The regulation range of evaporator
concentration is 0~5 vol%. Among
Halothane, Enflurane, Isoflurane and
Sevoflurane, one can be chosen for application
as required by the customer. And vaporizers
that are imported with original packaging are
also available.
Respiratory circuit working mode: all-close, semi-close, semi-open
releasing pressure: 0.5~7 kPa
Respiratory bellows bellows for adults, bellows for children
tidal volume range:0~1,500 ml
Ventilator(Ventilator DefinitionandVentilator Function)
Display mode High-definition 5.7” LCD screen display
Ventilation mode IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH
Ventilation parameters Tidal volume 50~1500ml
Rate 2~99bmp
SIMV rate 2~20bpm
I:E 2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range 1.0~6.0 kPa
SIGH 1.5 times the inspiratory time
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
Monitoring of oxygen concentration (21%~100%)
Security Alarm System
Oxygen Concentration alarm upper limit setting range (50%~100%)
low limit setting range (15%~50%)
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
no tidal volume inputfor 15 seconds
Power alarm
Power AC220V±10%50Hz±1Hz
(UPS, Storage battery)
Items within brackets are optional.

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *
PDF Download
test content
FAQ

1. How long is the warranty?
2 years.

2. Can I choose other language?
It depends. Most machines have multiple language.

3. What certificate do you have?
Generally, most machine have CE, ISO, FSC. Some have FDA.

4. How long is the delivery?
About 4 days

5. How can I pay?
Paypal, Western Union, T/T, L/C, Trade Assurance, Money Gram etc. are accepted.

1. Can the medical incinerator burn dead body?
No, It is a non-hazardous treatment device commonly used in medical waste, such as blood cotton, needles, and disposable syringes

2. Can a medical incinerator use gasoline?
No, only diesel or natural gas liquefied gas.

What type of gas does the body cabinet compressor use?
Secop's compressors use R134a refrigerant. The refrigerant is universal and easy to buy. The refrigerant used in domestic compressors is r12, which is easy to purchase in the domestic market.

4. Does the body cabinet need to be installed before using?
No need to install. Plug it in directly. But if it is shipped by air, the refrigerant needs to be pumped out and refilled before use.

5. Is there an analysis segment for the human body analyzers MSLCA01, MSLCA02, MSLCA03, MSLCA04?
The MSLCA01 Body Analyzer does not have this function, MSLCA02, MSLCA03, MSLCA04 have the function of segmental fat, segmental moisture analysis, edema coefficient analysis, detailed body water analysis, intracellular water, extracellular water, and body water status.

6. Can the body analyzer be OEM?
It is possible when it reaches a certain amount. At present, we are all shipping from neutral machines.

7. What languages ​​does the body analyzer support?
MSLCA01 supports French, Italian, German, Portuguese, Spanish, Russian, English, Simplified Chinese, and Traditional Chinese. MSLCA02, MSLCA03, MSLCA04 support German, English, Simplified Chinese, Traditional Chinese. Lhe language needs to be confirmed in advance.

8. Can an endoscope camera connect to a monitor?
Yes, you can choose different size: 15 inches, 21 inches, 24 inches and 26 inches.

9. How often does one need to change oil in vacuum pump?

The vacuum pump oil is changed once every six months, and the pump oil is changed for 200 hours according to the frequency of use. If the catch water is overloaded, there will be a small amount of water to the vacuum pump part and then the cold trap, so the pump oil must be changed.

10. How high the degrees can the MSLFV02 refrigerator do?
Cold trap -40 degrees, plate temperature -35 degrees. This model is used for food and vegetables.

11. Can endoscopes add an extra camera?
Yes, we generally do not advise customers to purchase two cameras because the camera is the most important component of the entire device, so the price is relatively high. Of course, if customers want to buy, it is ok.

Relevant articles
test content
Inquire Now

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.