MSLGA06 surgical operation anesthesia machine

MSLGA06 surgical operation anesthesia machine
$9,999.00

Availability: In stock

Model No:MSLGA06 Brand:Medsinglong Service:Medsinglong after-sales support. Contact us: Cindy@medmsl.com Keywords:Selling Well MSLGA06 Used In Hospital Surgical Operation Anesthesia Machine
OR
Description

Details

Selling Well MSLGA06 Used In Hospital Surgical Operation Anesthesia Machine - Buy Anesthesia Machine,Operation Anesthesia Machine,Hospital Anesthesia Machine Product on MEDSINGLONG GLOBAL GROUP CO.,LIMITED
We are professional supplier of all kind of respiratory equipment,medical anesthesia machine

1. Medical anesthesia machine

2. Vertical anesthesia equipment

3. Mobile anesthesia machine

4. Anesthesia gas machine

 

anesthesia machine price - MSLGA06

Main body

High-strength engineering plastic rack, light, 

beautiful and corrosion resistant

Scope of application

adult, child

Gas source

O2: 0.27~0.55MPa    N2O: 0.27~0.55MPa

Flow meter

 

O2 : 0.1~1.0L/min   1.1~10L/min

N20: 0.1~1.0L/min     1.1~10L/min

O2, N2O linkage and N2O Stopper

When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.

Flow rate of rapid oxygen supply

25~75L/min

Low oxygen pressure alarm (Oxygen Alarm)

There will be sound alarm when the oxygen

pressure < 0.2MPa

Vaporizer (Vaporizer Definition and Vaporizer Construction)

it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.

Respiratory circuit

working mode: all-close, semi-close, semi-open

APL: 0.5~7 kPa

Respiratory Bellows

 bellows for adults, tidal volume range:0~1500 ml

         bellows for children, tidal volume range:0~300 ml

anyone can be chosen for application as 

required by the customer

Ventilator (Ventilator Definition and Ventilator Function)

Display mode

high-definition 5.7” LCD display

Ventilation mode

IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

Ventilation parameters

Tidal volume

20~1500 ml

Rate

1~99 bpm

SIMV rate

2~20 bpm

I:E

4:1~1:8

Inspiratory trigger pressure

-1.0~2.0 kPa

PEEP

0~2.0 kPa

Pressure range

1.0~6.0 kPa

SIGH

1.5 times the inspiratory time

(70-150 adjustable)

 

Parameters for ventilation monitoring

tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform,PEEP,inspiratory trigger pressure, Inspiratory platform, autonomous inspiratory rate, lung compliance, airway resistance, flow-volume loop, pressure-volume loop

Monitoring of oxygen concentration

(21%~100%)

Security Alarm System

Oxygen Concentration alarm

upper limit setting range  21%~100%

low limit setting range    10%~80%

Airway pressure alarm

upper limit setting range  0.3~6.0 kPa

low limit setting range     0.2~5.0 kPa

Per-minute ventilation volume alarm

upper limit setting range   3.0~30L/min

low limit setting range    1.0~10L/min

Sustained high-pressure alarm

it will give alarm when stress have consistently been higher than 2.5 kPa 

Suffocation alarm

it will give sound and light alarm if there is no tidal volume input for 15 seconds

Power alarm

Power

AC 220V±10%     50Hz±1Hz(UPS, Storage battery)

(Mechanical Arms) 

(End-expiratory CO2 monitoring)

Items within brackets are optional.

Relate hot sale and cheap portable anesthesia machine

 

MSLGA07PLUS MSLPA01 MSLVM14
mechanical ventilation MSLPA01
MSLGA15 MSLVM06 MSLMN31

MSL TEAM picture 

medsinglong certificate

medsinglong After-sales service

Welcome to medicalequipment-msl.com.

If you have any demand in medical equipment, please feel free to contact cindy@medicalequipment-msl.com.

MSL coupon

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *
PDF Download
test content
FAQ

1. How long is the warranty?
2 years.

2. Can I choose other language?
It depends. Most machines have multiple language.

3. What certificate do you have?
Generally, most machine have CE, ISO, FSC. Some have FDA.

4. How long is the delivery?
About 4 days

5. How can I pay?
Paypal, Western Union, T/T, L/C, Trade Assurance, Money Gram etc. are accepted.

1. Can the medical incinerator burn dead body?
No, It is a non-hazardous treatment device commonly used in medical waste, such as blood cotton, needles, and disposable syringes

2. Can a medical incinerator use gasoline?
No, only diesel or natural gas liquefied gas.

What type of gas does the body cabinet compressor use?
Secop's compressors use R134a refrigerant. The refrigerant is universal and easy to buy. The refrigerant used in domestic compressors is r12, which is easy to purchase in the domestic market.

4. Does the body cabinet need to be installed before using?
No need to install. Plug it in directly. But if it is shipped by air, the refrigerant needs to be pumped out and refilled before use.

5. Is there an analysis segment for the human body analyzers MSLCA01, MSLCA02, MSLCA03, MSLCA04?
The MSLCA01 Body Analyzer does not have this function, MSLCA02, MSLCA03, MSLCA04 have the function of segmental fat, segmental moisture analysis, edema coefficient analysis, detailed body water analysis, intracellular water, extracellular water, and body water status.

6. Can the body analyzer be OEM?
It is possible when it reaches a certain amount. At present, we are all shipping from neutral machines.

7. What languages ​​does the body analyzer support?
MSLCA01 supports French, Italian, German, Portuguese, Spanish, Russian, English, Simplified Chinese, and Traditional Chinese. MSLCA02, MSLCA03, MSLCA04 support German, English, Simplified Chinese, Traditional Chinese. Lhe language needs to be confirmed in advance.

8. Can an endoscope camera connect to a monitor?
Yes, you can choose different size: 15 inches, 21 inches, 24 inches and 26 inches.

9. How often does one need to change oil in vacuum pump?

The vacuum pump oil is changed once every six months, and the pump oil is changed for 200 hours according to the frequency of use. If the catch water is overloaded, there will be a small amount of water to the vacuum pump part and then the cold trap, so the pump oil must be changed.

10. How high the degrees can the MSLFV02 refrigerator do?
Cold trap -40 degrees, plate temperature -35 degrees. This model is used for food and vegetables.

11. Can endoscopes add an extra camera?
Yes, we generally do not advise customers to purchase two cameras because the camera is the most important component of the entire device, so the price is relatively high. Of course, if customers want to buy, it is ok.

Relevant articles
test content
Inquire Now

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.