MSLMD23S Ophthalmological Ultrasonic A/B Scanner

MSLMD23S Ophthalmological Ultrasonic A/B Scanner
$9,999.00

Availability: In stock

Model No:MSLMD23S Brand:Medsinglong Service:Medsinglong after-sales support. Contact us: Cindy@medmsl.com Keywords:biometric measurements
OR
Description

Details

MSLMD23S Portable Ultrasonic A/B Scanner for Ophthalmology

biometric measurements

MSLMD23S Portable Ultrasonic A/B Scanner Introduction

The Ultrasonic A/B Scanner for Ophthalmology is an ultrasonic imaging instrument specialized in ophthalmological diagnosis. It consists of a main unit, a power adaptor, a 10MHz B-Probe, a 20MHz B-Probe, a 10MHz A-Probe, a footswitch, a keyboard and a mouse.

The 10MHz B-Probe applies to normal ophthalmological ultrasonic diagnosis; and the 20MHz B-Probe applies to observation of details of intraocular and retina structure.

Patients with eyelid trauma and severe eye infection are prohibited from using B-Scan, and patients with keratitis and cornea trauma are prohibited from using A-Biometric scan.
The A-Biometric scan should be used cautiously in patients without independent behavior abilities or those highly sensitive to contact-mode measurements, whose ineffective cooperation may result in inaccurate measurements.

MSLMD23S Portable Ultrasonic A/B ScannerSoftware Version

MD24S V1.0.
ocular biometry

MSLMD23S Portable Ultrasonic A/B ScannerExpected Service Life

Based on the experience of products sold (and considering technology upgrade cycle), as well as the aging of major parts - transducer which will probably reduce the basic performance, the product's expected service life is determined as five years according to the normal usage of six hours each working day. (Service life may extend if the major parts, like the probe, are returned to the manufacturer for upgrade.)

MSLMD23S Portable Ultrasonic A/B ScannerBasic Working Principle

a) B-Mode: Under the excitation of electric pulse, the 10MHz/20MHz ultrasound transducer emits ultrasonic pulse into eye and receives reflective echo from the surfaces of different tissue, thus forming real-time two-dimensional image of eye tissue.

b) A-Mode: Under the excitation of electric pulse, the 10MHz ultrasound transducer emits ultrasonic pulse into eye and receives reflective echo from the surfaces of three different tissues of anterior chamber, lens and vitreous body. The transmitting time of ultrasonic wave in different tissues are measured and the distance of each part will be calculated according to the acoustic velocity of different tissues and then the axial length (AL) will be calculated.

ultrasound biometry

MSLMD23S Portable Ultrasonic A/B ScannerWorking Conditions

Adaptor
1. Working Temperature: 5℃-40℃;
2. Relative Humidity: lower than 80%;
3. Input Voltage of Power Adaptor: AC 100-240V, 50/60Hz;
4. Atmospheric Pressure: 70-106kPa.
Main Unit
1. Working Temperature: 5℃-40℃;
2. Relative Humidity: lower than 80%;
3. Input Voltage of Main Unit: DC 12V, 4A
4. Atmospheric Pressure: 70-106kPa.
Basic Parameters
1. Nominal Ultrasound Frequency: B-Probe: 10MHz/20MHz Available, A-Probe: 10MHz;
2. User Interface: monitor, keyboard, mouse, touch screen and footswitch;
3. Monitor: resolution≥1024×768, gray scale≥256;
4. Keyboard and Mouse: USB interface, wireless keyboard and mouse; see Annex D for the main specification;
5. Output Interface: 4×USB2.0 and HDMI interface;
6. Net Weight: 5.5kg;
7. Size: 34cm x 31cm x8cm.

MSLMD23S Portable Ultrasonic A/B ScannerSpecifications

B-mode
1. Scanning Method: mechanical sector scan;
2. Display Mode: B, B A;
3. Scanning Angle: 53;
Display Depth Adjustable Range: 10MHz: 28mm~60mm; 20MHz: 19 mm~40mm;
4. Variable Delayed Depth: 10MHz: 0 mm~15 mm; 20MHz: 0 mm~10mm;
5. Gain Control Range: 1-105dB;
6. TGC: -20dB~20dB with dynamic range, manual sectional adjustment (6-section adjustable);
7. Grey Scale: 256 Levels;
8. Frame Rate: 10fps;
9. Image Saving: 100 images;
10. Dynamic Loop: 10s/100 images, loop or frame-by-frame playback;
11. Image Processing and Signal Post-processing: Frame-Averaging, Pseudo-Color Codes, and Gamma Correction
12. Axial Resolution
a) 10MHz Probe: No more than 0.1mm;
b) 20MHz Probe: No more than 0.08mm;
13. Lateral Resolution
a) 10MHz Probe: No more than 0.2mm;
b) 20MHz Probe: No more than 0.15mm.
A-mode
1. AL Biometric Measuring Range: Axial Length (AL): 15mm-40mm;
2. AL Biometric Measuring Accuracy: No more than ±0.05mm;
3. Total Gain: 98dB, user’s gain adjustability: 1~60dB;
4. Measuring Mode: 5 groups (Normal, Aphakic, Special, Cataract and Manual Measurement);
5. Measuring Method: Immersion/Contact;
6. IOL calculation: SRK-T, SRK-II, BINK-II, HOLLADAY, HOFFER-Q and HAIGIS;
7. Support IOL calculation after refractive surgery, two groups of formulas can be calculated contrastively and displayed simultaneously.
8. Automatic measurement and 10 groups averaging and display standard deviation.
9. Up to 8 groups of IOL constants can be stored.
Safety
1. The electrical safety of this product shall be in accordance with requirements of IEC60601-1, IEC60601-1-2 and IEC60601-2-37.
2. For information on Acoustic Output Parameters, please see Annex B.

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *
PDF Download
test content
FAQ

1. How long is the warranty?
2 years.

2. Can I choose other language?
It depends. Most machines have multiple language.

3. What certificate do you have?
Generally, most machine have CE, ISO, FSC. Some have FDA.

4. How long is the delivery?
About 4 days

5. How can I pay?
Paypal, Western Union, T/T, L/C, Trade Assurance, Money Gram etc. are accepted.

1. Can the medical incinerator burn dead body?
No, It is a non-hazardous treatment device commonly used in medical waste, such as blood cotton, needles, and disposable syringes

2. Can a medical incinerator use gasoline?
No, only diesel or natural gas liquefied gas.

What type of gas does the body cabinet compressor use?
Secop's compressors use R134a refrigerant. The refrigerant is universal and easy to buy. The refrigerant used in domestic compressors is r12, which is easy to purchase in the domestic market.

4. Does the body cabinet need to be installed before using?
No need to install. Plug it in directly. But if it is shipped by air, the refrigerant needs to be pumped out and refilled before use.

5. Is there an analysis segment for the human body analyzers MSLCA01, MSLCA02, MSLCA03, MSLCA04?
The MSLCA01 Body Analyzer does not have this function, MSLCA02, MSLCA03, MSLCA04 have the function of segmental fat, segmental moisture analysis, edema coefficient analysis, detailed body water analysis, intracellular water, extracellular water, and body water status.

6. Can the body analyzer be OEM?
It is possible when it reaches a certain amount. At present, we are all shipping from neutral machines.

7. What languages ​​does the body analyzer support?
MSLCA01 supports French, Italian, German, Portuguese, Spanish, Russian, English, Simplified Chinese, and Traditional Chinese. MSLCA02, MSLCA03, MSLCA04 support German, English, Simplified Chinese, Traditional Chinese. Lhe language needs to be confirmed in advance.

8. Can an endoscope camera connect to a monitor?
Yes, you can choose different size: 15 inches, 21 inches, 24 inches and 26 inches.

9. How often does one need to change oil in vacuum pump?

The vacuum pump oil is changed once every six months, and the pump oil is changed for 200 hours according to the frequency of use. If the catch water is overloaded, there will be a small amount of water to the vacuum pump part and then the cold trap, so the pump oil must be changed.

10. How high the degrees can the MSLFV02 refrigerator do?
Cold trap -40 degrees, plate temperature -35 degrees. This model is used for food and vegetables.

11. Can endoscopes add an extra camera?
Yes, we generally do not advise customers to purchase two cameras because the camera is the most important component of the entire device, so the price is relatively high. Of course, if customers want to buy, it is ok.

Relevant articles
test content
Inquire Now

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.