Cart0Item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.
  • High Frequency Mobile Radiography Unit - MSLMX06 High Frequency Mobile Radiography Unit - MSLMX06

High Frequency Mobile Radiography Unit - MSLMX06

Quick Overview

Brand:MedsinglongService:Medsinglong after-sales support.Contact us: Cindy@medmsl.com

Availability: In stock

$9,999.00

Details

1. 3.5kW Medical mobile x-ray machine

2. High frequency mobile x-ray machine

3. Mobile x-ray unit

4. Mobile x-ray equipment

5. 3.5kW Mobile Radiography equipment

《The introdution of x-ray machine》- Have you ever heard of the story about the discovery of X-ray? How was X-ray discovered? Could you figure out some uses of X-ray machine?...

MSLMX06 Mobile Radiography Unit

One mobile stand with X-ray generator and control panel.

The MSLMX06 is designed primarily for applications in wards. However, it is also ideally suitable for use as a mobile diagnostic unit to support other hospital disciplines.

Features

1 Mobility

The MSLMX06 can be wheeled anywhere: a large revolving handle, supported by an extremely easy-to- manoeuvre trolley means it can be directed precisely and quickly to the patient, through narrow corridors and between closely-spaced rows of beds. operated from a standard socket, wherever it is needed.

Easy to manage

The unobtrusive design means that the operator can concentrate, without distraction, on the procedure in hand. The hygienically designed operating panel was conceived with the user in mind: clear symbols make for easy setting of the parameters, and the values can be immediately checked on the display panel.

An integrated microprocessor ensures that perfect results are obtained for every exposure.

3 Unique

The newly developed converter type generator technology with 3.5kW output makes the MSLMX06 the most efficient mobile X-ray unit in its class.

Main Technical Parameter:

1 System Block

MSLMX06 is one mobile X-ray radiography unit.

It is consist of Stand and X-ray generator. The X-ray generator is type of HF converter and DC high voltage generator. System block is as follow:

Specifications

Generator

Type

HF converter, DC High Voltage

Voltage

Adjustable in steps of 1 kV from 40 to 110 kV

mAs Values

Adjustable in 22 steps from 1 to 160 mAs, meeting R’10 noise reduction . It is 1, 1.3, 1.6, 2, 2.5, 3.2, 4, 5, 6.3, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 and 160.

Output

3.5kW (100kV/35mA)

110kV 30mA

80kV 46mA

40kV 70mA

Working mode

Run in intermittent loading

Tolerance

kV /- 10 %

mAs /- (10 % 0.2mAs)

X-ray Tube (What is an x-ray tube? The construction of x-ray tube)

Type

XD6A-0.5,3.5 / 125; Stationary Anode

Material of Target

Tungsten

Angle of Target

15°

Focal Spot Size

1.5mm

Normal Voltage

110kV

Max. Heat capacity

57kJ (76kHU)

X-ray Tube Assembly

Power

3.5kW

Max. Normal Voltage

110kV

Fixed filter

2.7mmAl

Isolation type

Oil

Temperature Protective

55°C Temperature relay

Max. Heat capacity

800kJ (1040kHU)

Max continuous heat dissipation

260W

Collimator

Max. Field at 1m

43cm X 43cm

Data for Radiation

Total Filter

2.8mmAl

Leakage Radiation

Avg. Air Kerma Rate less than1.0mGy/h at all places that around and 1m distance from focal spot.(Loading set 110kV and work 10000mAs max in 1 hour)

Irremovable filter :

2.8mmAl

Leakage Current

Leakage current to Ground

Normal:Not more than 2.5mA

Single Fault:Not more than 5mA

Leakage current to Covers

Normal:Not more than 0.1mA

Single Fault:Not more than 0.5mA

Power supply

Voltage

220V ac

Max. voltage tolerance

/-10%

Frequency

50Hz

Max. Frequency deviation

/-1Hz

Max. impedance

0.60W

Fusing

220V,16A Slow

Environment

Temperature

10 to 40°C

Relative Humidity

30 to 75%

Atmospheric Pressure

700 to 1060hPa

Movement and Weight

Distance from Tube Focal to Floor

50cm to 190cm, adjustable

Rotation around arm of Tube assembly

90°to -90°

Rotation around axis of Tube assembly

-45°to 90°

Weight

102kg

Photo voltage rang:40 ~ 110Kv

collimator position adjustment ± 180 Around the stent tube rotation: 180 ° / -45

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *