500ma diagnosis radiology x ray equipment MSLCX26

Quick Overview

Brand:MedsinglongService:Medsinglong after-sales support.Contact us: Cindy@medmsl.com

Availability: In stock

$9,999.00

Details

Features of 500ma diagnosis radiology x ray equipment MSLCX26

  • 1)Double table, double tube 500mA, 125kV, single-phase full-wave rectifier bridge.
  • 2) The machine is equipped with Xray tube capacity protection, rotating anode start protection, SCRcontrolled radiographic timing diagram, the fluoroscopy load time cumulative device and the Xray tube overtemperature protection devices, to ensure longterm safe operation of X-ray tube.
  • 3) The fluoroscopy table has wide rotation range, table face movable, many film specifications, and easy to operate and equipped with a radiation and scattering of radiation sufficient protection to ensure the safety of operator and patients.
  • 4) multi-function radiography table, with no ceiling-to-floor orbit, double rope protection against falling to protect pillar, beautiful in appearance, table’s vertical and horizontal movement can be flexible, the movement and rotation of Xray tube assemblies flexible And lightly, electromagnetic brake, to holds the respective cassette.
  • 5) With X-TV system and tomography device interface.
  • 6) Suitable for small and medium sized hospitals in the Xray fluoroscopy, spot film radiography, filter


Specification of 500ma diagnosis radiology x ray equipment MSLCX26

  • Fluoroscopy Current: 0.3-5mA continuous currency
  • Fluoroscopy Voltage: 45-110KV continuous voltage
  • Radiography Current: 30-500mA adjustable by steps
  • Radiography Time: 0.02-5S adjustable 23 steps
  • Radiography Voltage: 45-125KV continuously adjustable
  • X-Ray tube Model: XD51.20-40/125kV

Fluoroscopy

  • Tube currency: 0.3-5mA continuous currency 
  • Tube voltage :  50-110KV continuous voltage

Radiography 

  • Tube currency:  100-400mA shift 
  • Tube voltage:  45-125KV continuous voltage
  •  Exposure time: 0.02-5s23 shift

Power

  • Voltage : 380V±10%
  • Frequency : 50Hz±1Hz
  • Capacity : ≥30KVA
  • Inner resistance: ≤0.3Ω

X-ray assembly

  • Type of x-ray tube: XD52-30.50/125
  • Focus: 1×1.2×2 double focal
  • Rated rotate speed of anode: 2800r/min

Changed beam limited device

  • Diagnosis table YS09D: Automatic, adjusted field of view
  • Radiograph table YS11S: Manually adjusted field of view, luminosity≥100LX

C15 Diagnostic table

  • Rotate of table: -15°~0°~90°automatic
  • Moving table: Automatic 700mm distance moving lengthways
  • Distance of focal table: 400mm
  • High of table: 820mm

Spot film device

  • Scope moving :Up and down/ 600mm, Left and right/±100mm, Forward and backward/300mm
  • Way of locking: Electromagnetism locking
  • Radiography item: 5×7,8×10,10×12,11×14

CDGI Multi function   radiography table

  • Moving table: Lengthways  ±600mm &  Across ±120mm  Electromagnetism locking
  • Mobile beam filtration grid
  • Grid density: 28L/cm
  • Grid ratio: 8:1
  • Focusing distance: 100cm
  • Scope of moving: ≥600mm
  • Radiography item: 5”×7”,8”×10”,10”×12”,11”×14”, 12”×15”,14”×14”,14”×17”
  • Distance from surface to film: 75mm
  • Height of bed: 700mm
  • Moving pillar: ±180°,per 90°orientation, moving lengthways ≥1500mm
  • Bulb tube: Rotate the cross arm±180,ascend and descend 1100mm.

Option

  • LSJ pillar radiography frame
  • The scope of ascend and descend : 1450mm
  • The minimum distance from focal spot: 380mm
  • Radiography item: 8”×10” 10”×12” 11”×14”      12”×15”14”×14” 14”×17”
  • Fixed beam filtration role
  • Grid density: 40L/cm.
  • Grid radio: 10:01
  • Focal distance:180cm.

Product Detail and Usage Pictures - 500ma diagnosis radiology x ray equipment MSLCX26

500ma diagnosis radiology x ray equipment MSLCX26

Contact US for more videos about: 500ma diagnosis radiology x ray equipment MSLCX26