Details
Main Features
- 12.1" color TFT screen
- Multi‐channel display
- Big font interface
- ST and arrhythmia analysis
- Drug dose calculation and titration table
- OxyCRG dynamic view display
- Respiration monitoring with apnea alarms
- Alarm review, arrhythmia review
- Patient info. Input
- Anti‐defibrillation design
- NIBP over pressure protection
- Plug‐in rechargeable battery, AC/DC available.
- Supporting wire or wireless network.
MSL vet patient monitor for sale MSLMP06 Technical Specifications
ECG
- Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
- Lead selection: I, II, III, avR, avL, avF, V
- Wavef orm : 2 ch
- Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
- Lead selection: I, II, III,
- Wave form : 1 ch
- Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
- HR and Alarm Range: Adult 15 ~ 300 bpm / Neo/Ped 15 ~ 350 bpm
- Accuracy: ±1% or±1bpm, which is greater
- Resolution : 1 bpm
- Sensitivity: > 200 (uVp-p)
- Differential Input Impedance: > 5 M
- CMRR
- Monitor > 105 dB
- Operation > 105 dB
- Diagnosis > 85 dB
- Electrode offset potential :±300mV
- Leakage Current: < 10 uA
- Baseline Recovery: < 3 S After Defi.
- ECG Signal Range: ±8 m V ( Vp-p )
- Bandwidth
- Surgery 1 ~ 20 Hz
- Monitor 0.5 ~ 40 Hz
- Diagnostic 0.05 ~ 130 Hz
- Calibration Signal: 1 (mVp-p), Accuracy:5%
- ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
- ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available
Respiration
- Method Impedance between R-F(RA-LL)
- Differential Input Impedance > 2.5 MΩ
- Measuring Impedance Range 0.3~3 Ω
- Base line Impedance Range 200~4 KΩ
- Bandwidth 0.1~2.5Hz
- Resp. Rate Measuring and Alarm Range
- Adult 0 ~ 120 Brpm
- Neo/Ped 0 ~ 150 Brpm
- Resolution 1 Brpm
- Accuracy ±2 Brpm
- Apnea Alarm 10 ~ 40
NIBP
- Method Oscillometric
- Mode Manual, Auto, STAT
- Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
- Measuring Period in STAT Mode 5 Min
- Pulse Rate Range 40 ~ 240 bpm
- Alarm Type SYS, DIA, MEAN
- Measuring and alarm range
- Adult Mode
- SYS 40 ~ 270 mmHg
- DIA 10 ~ 215 mmHg
- MEAN 20 ~ 235 mmHg
- Pediatric Mode
- SYS 40 ~ 200 mmHg
- DIA 10 ~ 150 mmHg
- MEAN 20 ~ 165 mmHg
- Neonatal Mode
- SYS 40 ~ 135 mmHg
- DIA 10 ~ 100 mmHg
- MEAN 20 ~ 110 mmHg
- Resolution 1mmHg
- Accuracy Maximum Mean error ±5mmHg / Maximum Standard deviation ±8mmHg
- Overpressure Protection
- Adult Mode 297±3 mmHg
- Pediatric Mode 240±3 mmHg
- Neonatal Mode 147±3 mmHg
SpO2
- Measuring Range : 0 ~ 100 %
- Alarm Range: 0 ~ 100 %
- Resolution : 1 %
- Accuracy: 70% ~ 100% 2 % 0% ~ 69% unspecified
- Actualization intervalabout : 1 Sec.
- Alarm Delay: 10 Sec.
- Pulse Rate: Measuring and Alarm Range 20~300 bpm
- Resolution : 1bpm
- Accuracy: ±3bpm
TEMP
- Channel: 2
- Measuring and Alarm Range: 0 ~ 50 ℃
- Resolution: 0.1 ℃
- Accuracy: ±0.2 ℃
- Actualization interval about: 1 Sec.
- Average Time Constant: < 10 Sec.
IBP
- Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
- Measuring and alarm range
- ART 0 ~ 300 mmHg
- PA -6 ~ 120 mmHg
- CVP/RAP/LAP/ICP-10 ~ 40 mmHg
- P1 / P2-10 ~ 300 mmHg
- Press Sensor Sensitivity 5 uV/V/mmHg
- Impedance 300-3000Ω
- Resolution 1 mmHg
- Accuracy ±2% or 1mmHg which is greater
- Actualization interval about 1 secretar