MSL Used ventilator machine MSLVM09 for sale Main Features

  • A.Gas drive and electrical control, time-pressure switching and pressure limit control.
  • B. A high-brightness LED digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc.
  • C.A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation.
  • D.In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself.

Operating Principles

  • Driven by compressed medical oxygen, the MSLVM09 ventilator uses a gas ejector based on Venturi effect to form a mix of medical oxygen and ambient atmosphere which is delivered through the ventilator circuit into the airway in the patient for mechanical ventilation.
  • During such process, a fast solenoid valve, a highly sensitive flow sensor, a pressure sensor and a single-chip microcomputer control system are used to measure, adjust and control such parameters as the ventilation pressure, ventilation time, throughput, etc. to the patient.
  • This ventilator can display in real time the following important parameters:
    • -Operating mode and respiratory rate;
    • -Ventilator control frequency set by medical staff;
    • -Tidal volume of each breath in the patient;
    • -Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
    • -Expiratory phase and inspiratory phase and actual respiratory rate;
    • -Minute volume;
    • -Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;
    • -Real-time variation in internal airway pressure.
operating conditions
  • -Ambient temperature: 10 ~ 40℃, relative humidity: no higher than 80%.
  • -Atmosphere pressure: 86kPa ~ 106kPa
  • -Gas source requirement: medical oxygen source with a pressure ranging from 280 to 600kPa and a flow rate
  • of 50L/min (containing no fresh air).
  • -Power supply requirements: AC 220V±10%, 50±1Hz and 30VA, well grounded.
  • ventilator price | ventilator machine price 

Basic Functions
  • -Sigh (deep breath);
Ventilation Modes
  • -SIPPV
  • -IPPV
  • -IMV
  • -SIMV
Technical Data
  • -Tidal volume range: no less than 50 to 1200ml, permissible deviation: ±20 %.
  • -Maximum minute ventilation: ≥ 18 L/min, permissible deviation: ±20 %.
  • -Oxygen concentration of output gas: <45 %.
  • -Controlled ventilation (IPPV) frequency range: 6 ~ 60times/min, permissible deviation: ±15 %.
  • -I:E ratio: 1:1.5, 1:2.0, 1:2.5 and 1:3.0, permissible deviation: ±15%.
  • -Maximum safety pressure: ≤6.0 KPa
  • -Settable maximum operating pressure: 5~6.0 KPa (gas source pressure ranging from 280kPa to 600kPa).
  • -Oxygen consumption: the variation in the gas pressure in the cylinder should be less than or equal to
  • 1.5MPa/h when the ventilator operates on a 12250KPa / 40L medical oxygen cylinder continuously for one hour.
  • -Inspiration triggering pressure range: -0.4 ~ 1.0 KPa, permissible deviation: ±0.15 KPa
  • -Time to switch between controlled and assisted ventilation modes: 6s, permissible deviation: +1 s, -2 s.
  • -Intermittent mandatory ventilation (IMV) frequency range: 1 to 12 times/min, permissible deviation: ±15%.
  • -PEEP range: no less than 0.1 to 1.0kPa.
  • -Sigh (deep breath): the inspiration time should be no less than 1.5 times of the original setting.
  • -Pressure limit range: 1.0~6.0kPa, permissible deviation: ±20 %
  • -The presentation of the spontaneous breathing frequency, overall respiratory rate and ventilation capacity is
  • refreshed once every minute.
  • -Continuous operation duration: the ventilator can operate continuously on a 24-hour basis on an AC utility main.
  • -Main unit net weight: 28kg, dimension (L×W×H): 410×300×1100 (mm).

Product Detail and Usage Pictures - Used ventilator machine price MSLVM09

Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09Used ventilator machine price MSLVM09

Contact US for more videos about: Used ventilator machine price MSLVM09

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Other people marked this product with these tags:

Use spaces to separate tags. Use single quotes (') for phrases.

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp