Multi-Parameter Patient Monitor MSLMP09

Quick Overview

Brand:MedsinglongService:Medsinglong after-sales support.Contact us: Cindy@medmsl.com

Availability: In stock

$9,999.00

Details

Touch Screen Multi-Parameter Patient Monitor MSLMP09

  • 12.1" color TFT touch screen
  • Windows style, Multi-channel display
  • Big font interface
  • ST and arrhythmia analysis
  • Drug dose calculation and titration table
  • OxyCRG dynamic view display
  • Respiration monitoring with apnea alarms
  • Alarm review, arrhythmia review
  • Patient info. Input
  • Anti-defibrillation design
  • NIBP over pressure protection
  • Plug-in rechargeable battery, AC/DC available.
  • Supporting wire or wireless network.
SP02
  • Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
  • Nellcor(TM)  OxiMax(TM) delivers excellent performance,
  • even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.
ECG
  • Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
  • Lead selection: I, II, III, avR, avL, avF, V
  • Wave form: 2 ch
  • Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
  • Lead selection: I, II, III,
  • Wavef orm:  1 ch
  • Gain:   2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
  • HR and Alarm Range: Adult    15 ~ 300 bpm/  Neo/Ped    15 ~ 350 bpm
  • Accuracy: ±1% or±1bpm, which is greater
  • Resolution:1 bpm
  • Sensitivity:  > 200 (uVp-p)
  • Differential Input Impedance :> 5 MΩ
  • CMRR:
    •  Monitor > 105 dB
    •  Operation > 105 dB
    •  Diagnosis > 85 dB
  • Electrode offset potential :   ±300mV
  • Leakage Current: < 10 uA
  • Baseline Recovery: < 3 S After Defi.
  • ECG Signal Range:   ±8 m V ( Vp-p )
  • Bandwidth:   Surgery    1 ~ 20 Hz
  •  Monitor:0.5 ~ 40 Hz
  • Diagnostic:  0.05 ~ 130 Hz
  • Calibration Signal:       1 (mVp-p),  Accuracy:5%
  • ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
  • ARR Detecting:   Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,
  • R ON T, VT>2,BRADY, MISSED BEATS,
  •  PNP, PNC,Alarm Available,Review Available
Respiration
  • Method:    Impedance between R-F(RA-LL)
  • Differential Input Impedance       > 2.5 MΩ
  • Measuring Impedance Range          0.3~3 Ω
  • Base line Impedance Range          200~4 KΩ
  • Bandwidth:  0.1~2.5Hz
  • Resp. Rate: Measuring and Alarm Range
  • Adult 0 ~ 120 Brpm
  • Neo/Ped 0 ~ 150 Brpm
  • Resolution 1 Brpm
  • Accuracy ±2 Brpm
  • Apnea Alarm:    10 ~ 40 S
NIBP
  • Method:    Oscillometric
  • Mode:      Manual, Auto, STAT:    
  • Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
  • Measuring Period in STAT Mode     5 Min
  • Pulse Rate Range           40 ~ 240 bpm
  • Alarm Type:       SYS, DIA, MEAN
Adult Mode
  • SYS 40 ~ 270 mmHg
  • DIA 10 ~ 215 mmHg
  • MEAN 20 ~ 235 mmHg
  • Pediatric Mode
  • SYS 40 ~ 200 mmHg
  • DIA 10 ~ 150 mmHg
  • MEAN 20 ~ 165 mmHg
  • Neonatal Mode
  • SYS 40 ~ 135 mmHg
  • DIA 10 ~ 100 mmHg
  • MEAN 20 ~ 110 mmHg
  • Resolution:  1mmHg
  • Accuracy:    Maximum Mean error ±5mmHg
  •  Maximum Standard deviation ±8mmHg
  • Overpressure Protection          Adult Mode 297±3 mmHg
  • Pediatric Mode 240±3 mmHg
  •  Neonatal Mode 147±3 mmHg
SpO2
  • Measuring Range:       0 ~ 100 %
  • Alarm Range:  0 ~ 100 %
  • Resolution:   1 %
  • Accuracy: 70% ~ 100%  2 %
  •   0%  ~  69% unspecified
  • Actualization intervalabout      1 Sec.
  • Alarm Delay:  10 Sec.
  • Pulse Rate:   Measuring and Alarm Range 20~300 bpm
  • Resolution       1bpm
  • Accuracy ±3bpm
TEMP
  • Channe:  2
  • Measuring and Alarm Range: 0 ~ 50 ℃
  • Resolution:  0.1 ℃
  • Accuracy:  ±0.2 ℃
  • Actualization intervalabout:1 Sec.
  • Average Time Constant:< 10 Sec.
IBP
  • Label:   ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Measuring and alarm range       ART 0 ~ 300 mmHg
  •  PA -6 ~ 120 mmHg
  • CVP/RAP/LAP/ICP-10 ~ 40 mmHg
  •  P1 / P2-10 ~ 300 mmHg
  • Press Sensor: Sensitivity 5  uV/V/mmHg
  •  Impedance 300-3000Ω
  • Resolution: 1 mmHg
  • Accuracy:  ±2% or 1mmHg which is greater
  • Actualization interval : about 1 secretary
  • Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
  • Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

Product Detail and Usage Pictures - Multi-Parameter Patient Monitor MSLMP09

Multi-Parameter Patient Monitor MSLMP09Multi-Parameter Patient Monitor MSLMP09Multi-Parameter Patient Monitor MSLMP09Multi-Parameter Patient Monitor MSLMP09Multi-Parameter Patient Monitor MSLMP09Multi-Parameter Patient Monitor MSLMP09Multi-Parameter Patient Monitor MSLMP09

Contact US for more videos about: Multi-Parameter Patient Monitor MSLMP09

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Other people marked this product with these tags:

Use spaces to separate tags. Use single quotes (') for phrases.

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp

[profiler]
Memory usage: real: 48234496, emalloc: 46558224
Code ProfilerTimeCntEmallocRealMem