Cart0Item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

High precision Syringe Infusion Pump MSLIS13

Quick Overview

Brand:MedsinglongService:Medsinglong after-sales support.Contact us: Cindy@medmsl.com

Availability: In stock

$9,999.00

Details

Digital Electric Syringe Infusion Pump MSLIS13 Features

  • 4.3" color TFT LCD screen (LED backlight), with resolution 2724.3” color TFT LCD screen (LED backlight), with resolution 272×480
  • Three working modes: Rate/Time/Volume mode
  • Drug library with 210 kinds of medicine
  • Storage 1500 history records
  • Heating function, suitable for infusing in winter or there is requirement for the uid medication temperature
  • Support multi language display
  • A variety of visible and audible alarm, make infusion more safe
  • Standard: Drug library, History recorder, Heating function, Drop sensor
  • Optional: SpO 2 , NIBP
Electric Syringe Infusion Pump MSLIS13 Technical Specification
  • Infusion rate range
  • Adjustable drops rate range: 1 /min~400 drops/min (step: 1 drop /min)
  • Adjustable Low rate range: 1ml/h~1200ml/h (step 0.1ml/h)
  • Purge rate: 800ml/h
  • KVO rate:
    • 1ml/h (1~300ml/h)
    • 3ml/h (greater than 300ml/h)
  • Volume range: 1ml~9999.9ml (step: 0.1 ml)
  • Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
  • Time range: 1min~9999min (step: 1 min)
  • Infusion accuracy: Within ±3% (using calibrated high quality IV set)
  • Mechanical precision: within ±2%
  • Occlusion alarm threshold:
    • High: 800mmHg ± 200mmHg (106.7 kPa ± 26.7kPa)
    • Medium: 500mmHg ± 100mmHg (66.7 kPa ± 13.3kPa)
    • Lower: 300mmHg ± 100mmHg (40.7 kPa ± 13.3kPa)
  • Alarm: Infusion complete, Empty, Faulty signal, Misoperation, Occlusion, Door open, Air Bubble, Low battery, Setting error, AC power off, Idle
  • NIBP Range
  • Average deviation: ≤ ±5mmHg
  • Standard deviation: ≤ 8mmHg
  • Adult
    • SYS: 40mmHg~280mmHg
    • MEAN: 20mmHg~240mmHg
    • DIA: 10mmHg~220mmHg
  • Pediatric
    • SYS: 40mmHg~220mmHg
    • MEAN: 20mmHg~170mmHg
    • DIA: 10mmHg~160mmHg
  • Neonate
    • SYS: 40mmHg~135mmHg
    • MEAN: 20mmHg~110mmHg
    • DIA: 10mmHg~100mmHg
  • Static pressure
  • Range: 0mmHg~300mmHg
  • Deviation: 3mmHg
  • Resolution: 1mmHg
  • NIBP measurement mode
  • Manual
  • Cycle (automatic):
  • Optional interval: 1min, 2min, 3min,4min, 5min, 10min,15min, 30min, 60min, 90min
  • Fast: continuous NIBP measurement, interval is 5min
  • NIBP alarm
    • High pressure alarm: >90mmHg-160mmHg
    • Low pressure alarm: <50mmHg-90mmHg
    • Accuracy: ±5%
  • Overpressure protection
    • Adult: 280 mmHg ±10 mmHg
    • Pediatric: 237 mmHg ±3 mmHg
    • Neonate: 147 mmHg ±3 mmHg
  • SpO2
    • Range: 0%~100%
    • Resolution: 1%
    • Accuracy: 70% to 100%, precision is 2%
    • 0% to 69%, undefined
  • SpO2 alarm
  • Upper limit: 100%
  • Lower limit: 90%
  • Alarm value accuracy: 3%
  • Alarm time accuracy: 2s
  • Pulse rate
  • Range: 20bpm~300bpm
  • Resolution: 1bpm
  • Accuracy: 3bpm
  • Pulse rate alarm
    • Upper limit: 120bpm
    • Lower limit: 50bpm (default)
    • Alarm value accuracy: 5%
    • Alarm time accuracy: 2s
  • NIBP Cuff requirement
  • Human body contact materials: Waterproof cloth
  • Adult: Arm circumference: 25~35cm
  • Bladder size: 13.1cm×23.5cm
  • SpO2 sensor
  • Type: Finger clip type
  • Wire length: 3000mm, allowed deviation ±5%
  • Human body contact materials: Silicone
  • Size: 188 mm(L)×198 mm(W)×228 mm(H)
  • Net weight: 2.5kg

Product Detail and Usage Pictures - High precision Syringe Infusion Pump MSLIS13

High precision Syringe Infusion Pump MSLIS13

Contact US for more videos about: High precision Syringe Infusion Pump MSLIS13

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Other people marked this product with these tags:

Use spaces to separate tags. Use single quotes (') for phrases.

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp