CALL US NOW
+020 84899760
Cart0Item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Digital X-Ray Radiography System MSLHX12-Mobile Digital X-ray Scanner Machine

Quick Overview

Digital solutions can be affordable and still meet the high quality standards you need. With our Digital X-RayRadiography System MSLHX12 we offer a complete, scalable DR solution that can grow and develop with your facility. A solution that allows you to choose your own digital path at your own pace and that answers the need to deliver higher throughput with a lower cost per examination, all while pro-viding excellent image quality.

Availability: Out of stock

$999.00

Details

Features of Digital X-RayRadiography System MSLHX12

  • Digital Radiography made affordable
  • Floor-mounted easy for installation and operation
  • Supports additional software function
  • Compact appearance and structure

Specification of Digital X-RayRadiography System MSLHX12

  • Refer to the tabele below.

Client Usage Photos of Digital X-RayRadiography System MSLHX12

  • Please contact us for more details.

 

Item Technology Parameter
Flat panel Detector  Active Area: 430 (H) * 360 (V) mm, (14" * 17")
Pixel matrix: 2500*3052
Pixel Pitch: 140µm
A/D Conversion: 16 bit
Limiting Resolution: 3.4 LP/mm typ.
Cycle Time: Shot to Shot 6 sec
Image Capture Time: less than 2 sec
X-ray Conversion Layer: TFT  / Amorphous Silicon (a-Si) Photodiode
Generator Output Power: 50 kW
High frequency output: 50kHz
KVp: 40-150kVp
mA Range:10-630mA
Exposurer Timer Range: 0.001-6.3s
mAs Range : 0.5mAs-630mAs
Anatomical Programs (APR): 590
High voltage inverter frequency :50KHz
Input Phase/Voltage: 3 Phase, AC380V±10%,    50Hz±1Hz
X-ray tube Brand: Toshiba E7876X
Nominal focal spot value: 0.6mm (small focus)/1.2mm (large focus)
Rotation speed (min-1): 2700rpm@50Hz, 3200rpm@60Hz
Maximum tube voltage: 150kV
Maximum filament current: 370mA (small focus)/760mA (large focus)
Anode Heat Content: 230kHU (111KJ)
Max rating (0.1s) (kw): 20/46kW@ 50Hz
RAD Stand height: 2000mm
Detector rotation degree: ± 90°
Minimum vertical distance from center of the detector to the tube force spot: 1000mm-1800mm
Tube vertical movement : 1200mm
Tube lateral movement : 1800mm
Rotation of tube: +/- 180°
Image software and image processing Medical monitor: 23" LCD    DELL 
 Resolution: 1280 * 1024 (1M)   
Image processing Automatic or manual window position and window width adjustment, ROI window position and window width adjustment
Image turnover, circumgyrate
Image continuous enlarged, automatic or manual image cut
Rich label function
Image data manage Image adopt various of Inquire way (name, time,ID etc) 
Patient's information register
User individuation design set the interface and toolbar as you want
Host computer System: Windows 7
CPU: Intel Core 2 
Hard drive: 500GB
Internal storage: 4 G
VGA Card: High efficiency speedup card
Optical driver: DVD +/-RW
Fixed     table Standard table tope size: L2000mm * W800mm* 
Table height: 700mm
Floating way: 4 way
Weight capacity: 135Kg
Stand column Standard column height : 2100mm 
Detector vertical movement : 1100mm
Floating way: 1 way
Collimator Control method: Manual
The average brightness of the light field:>150lux
Input power: 10A  150W,AC24V
Software function Patient registration and data edit
Expose parameter adjustion
image view
image process and output
Data mannagement
DICOM 3.0 

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp

[profiler]
Memory usage: real: 47710208, emalloc: 46202816
Code ProfilerTimeCntEmallocRealMem