Cart0Item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

C-shape Open MRI System MSLMRI12-Hospital Magnetic Resonance Imaging System MRI

Quick Overview

Magnetic Resonance Imaging System MSLMRI12 provides not only conventional pulse sequences and clinical diagnosis functions, but also provides advanced functional applications, for instance, 3d angiography and water imaging. It applies brand new annex apex operating system which ensures easy operation and fast diagnosis.

Availability: In stock

$999.00

Details

Features of C-shape Open MRI System MSLMRI12

  • Full-scale upgraded FSE
  • Fast hydro-imaging for crisp display of MRCP and MRU
  • Good water-fat suppression and water-fat separation imaging
  • DWI with higher B value 
  • Thin slice and small FOV imaging make high resolution display of small organs available 
  • Breath-hold scan eliminates motion artifact for chest and abdomen
  • Over sampling provides flexible FOV imaging


Specification of C-shape Open MRI System MSLMRI12

  • Please refer to the table below.


Client Usage Photos of C-shape Open MRI System MSLMRI12

  • Please contact us for more details.


MSLMRI12 Specification
No. Description Parameter
1 Magnet System
1.1 Magnet Type Permanent Magnet Automatic constant temperature system
1.2 Field Strength 0.4T
1.3 Magnet Shape C-shape
1.4 Homogeneity(40cm,DSV,VRMS) ≤2.0ppm
1.5 Shim Method Active/Passive
1.6 Magnet Vertical Gap (Cover) 40cm
1.7 Magnetic Pole Dia. (Exclude Cover) 137cm
1.8 Accessibility(Horizontal Opening Angle) 320°
1.9 5 Gauss fringe field X-axis: horizontal ≤2.5m Y-axis: Vertical ≤2.5m Z-axis: horizontal ≤2.5m
2 Patient Couch and Communication
2.1 Patient Couch Driven mode Motor-driven
2.2 Max. Patient Weight ≥200kg(440lbs)
2.3 Patient Positioning Tools Laser Light Localizer for positioning of center slice Motor-driven transfer to center of imaging volume
2.4 Position accuracy ±1mm
2.5 Emergency Call Key Yes
2.6 Intercom System Yes
3 Gradient System
3.1 Gradient Field Strength(Single Axis) ≥28mT/m
3.2 Gradient Slew Rate (Single Axis) ≥93mT/m/ms
3.3 Rise Time ≤0.3ms
3.4 Gradient Cooling System(Gradient coils and Power electronics) Air Cooling
4 RF System
4.1 RF System Type Digital Transmit and Receive signal processing
4.2 Number of RF Channels 4
4.3 Transmitter Amplifier Peak Power 6kW
4.4 RF Bandwidth of Receiver 1.25MHz
4.5 Head Coil Yes
4.6 Neck Coil Yes
4.7 Body/Spine Coil (17 inch) Yes
4.8 Body/Spine Coil (20 inch) Yes
4.9 Knee Coil Yes
4.10 Shoulder Coil Yes
5 Computer System
5.1 Host Computer DELL Computer (for MR)
5.2 System Software Windows 7
5.3 Operation Software APEX
5.4 CPU Clock rate 3.6GHz
5.5 Main Memory 2GB
5.6 Color LCD Monitor 19”
5.7 Keyboard and Mouse Standard
5.8 Image Reconstruction Speed(256 x 256 Matrix) 1500 FPS
5.9 Hard Disk 500GB
5.10 Image Storage Capacity(256 x 256 Matrix) 2,650,000 images
5.11 Media Driver DVD RW
5.12 DICOM 3.0 Yes
5.13 Ethernet Yes
5.14 Operation Console Yes
5.15 Operation Chair Yes
6 Scanning Parameter
6.1 Max. FOV 400mm
6.2 Min. FOV 5mm
6.3 Min. TE(SE) 5ms
6.4 Min. TR(SE) 11ms
6.5 Min. TE(GR) 1ms
6.6 Min. TR(GR) 3ms
6.7 Min. 2D Thickness 1.0mm
6.8 Min. 3D Thickness 0.1mm
6.9 Max. Image Matrix 1024x1024
7 Scanning Sequence & Imaging Technique
7.1 Spin Echo 2D/3D (SE 2D/3D) Yes
7.2 Fast Spin Echo 2D/3D(FSE 2D/3D) Yes
7.3 Single Shot FSE 2D/3D Yes
7.4 Inversion Recovery(IR) Yes
7.5 Fast Inversion Recovery(FIR) Yes
7.6 FLAIR Yes
7.7 T1-FLAIR Yes
7.8 Gradient Echo 2D/3D(GR 2D/3D) Yes
7.9 Fast GR 2D/3D Yes
7.10 Variable angle fast gradient echo Yes
7.11 Fat Imaging Yes
7.12 STIR Yes
7.13 SEDIXON Water-Fat Separation imaging Yes
7.14 TOF MRA(2D/3D) Yes
7.15 MRCP(2D/3D) Yes
7.16 MRU(2D/3D) Yes
7.17 MRM Yes
7.18 Fast Hydrograph Imaging Yes
7.19 Diffusion Weighted Imaging(DWI) Yes
7.20 Max. b Value 1000s/mm2
7.21 Breath Hold Technology Yes
7.22 Magnetization Transfer Contrast(MTC) Yes
7.23 Multi-slice and Angle-free Pre-saturation Yes
7.24 Saturation Tracking Yes
7.25 Maximum Intensity Projection(MIP) Yes
7.26 Minimum Intensity Projection(MinIP) Yes
7.27 3D Reconstruction Yes
7.28 Multi-planar Reconstruction(MPR) Yes
7.29 Multi-Artifacts Eliminating technology Yes
7.30 Checking with Part Metal Implant Yes
7.31 Online Image Filtration Yes
7.32 Online Post Procession Yes
7.33 3D Scout Yes
7.34 Scanning Protocol Preset Yes
7.35 Scanning Protocol Queue Waiting Yes
7.36 Advanced Image Post Processing Yes
7.37 Image Fusion Technology of Vascular Yes
7.38 Image Fusion Technology of Spine Yes
7.39 “Propeller”artifact suppression technology(For both head and abdomen) Yes

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp