Advanced ventilator equipment MSLVM12

Quick Overview

Brand:MedsinglongService:Medsinglong after-sales support.Contact us: Cindy@medmsl.com

Availability: In stock

$9,999.00

Details

Advanced ventilator equipment MSLVM12 Main Characteristics

  • MSLVM12 ventilator is a gas-driven, electrically controlled and multi-functional mechanism, which incorporates time and capacity switches and pressure restrictions. The main purposes of ventilator are to:
  • Provide the patients who are in a deadly danger with respiratory support at their most dangerous stage;
  • Protect patients in going through their dangerous period;
  • Ensure a successful basic treatment for further recovery;
  • Provide substitutes for anti-reversion respiratory muscle pathological changes or anti-reversion upper windpipe injury to maintain the patients' breathing function;
  • Provide breathing support for patients after sickness or during the recovery period after operation.
Main characteristics are stated as follows:
  • a.Gas-driven, electrical control, time-pressure switch, and pressure limit control
  • b.Have air-oxygen mixer particles of high-performance, can adjust the oxygen concentration conveniently and accurately.
  • c.Apply electronic PEEP, can make continuous adjustment of PEEP.
  • d.PTR has 2 kinds of trigger ways: Pressure trigger and flow trigger.
  • e. Apply highly and fast sensitive pressure sensor and flow sensor to airway pressure, gas flow detection,
  • control and display, and has ventilation auto-compensation
  • f. Many ventilator modes: VCV, PCV. PSV, SIMV. PSIMV(SIMV+PSV), CPAP.
  • g. Apply led, real-time displays these parameters, such as controlling frequency, tidal volume, ventilation, total breathing frequency, self respiratory rate, compliance, airway resistance, oxygen concentration, it also displays pressure and curve of flow vale to time.
  • h. P-V (Pressure-Volume), F-V (Flow-Volume).
  • i. When the ventilator runs abnormally or is incorrectly operated, it will trigger both audio and visual alarms to protect itself.
  • j. even if the power is off, no chokes will occur to the patients, for the respiration tubes are connected to the outer atmosphere.

MSL Advanced ventilator equipment MSLVM12 for sale Work Environment

  • Normal working conditions of PA-900B II:
  • Temperature: 10~40 Degree Celsius
  • Relative Humidity: ≤80%
  • Atmospheric Pressure: 86 kPa ~ 106 kPa
  • Gas: medical oxygen and compressed air of 280~ 600kPa
  • Power: AC220V±10%, 50±1Hz, 40VA, with ground protection.
The ventilator will do real-time display of these following parameters:
  •  Work mode and I/E ratio
  •   Pre-set controlling frequency
  •  Tidal volume per respiration
  •  The appearance of spontaneous respiration and its frequency
  •   Oxygen concentrator
  •   Plat form pressure and Airway peak pressure
  •   Compliance and airway resistance
  •  Real-time changes of airway internal pressure
  •  Display of Inspiratory status and Expiratory status, actual respiratory frequency
  •  Ventilation capacity per minute
  •   Airway pressure, respiratory frequency, tidal volume, alarm bounds of Ventilation
  • capacity per minute.
Basic functions
  •  Assistant Respiration, controlling respiration, autonomous respiration
  •   End-Inspiratory Halts
  •   PEEP
  •  Sigh (deep breath)
  •   Standby
  • Work Mode
  •  VCV (volume control ventilation)
  •  PCV (Pressure Control Respiration mode)
  •  PSV (Pressure supporting volume)
  •   IMV (Intermittent Mandatory Ventilation mode)
  •  SIMV (Simultaneous Intermittent Mandatory mode)
  •  CPAP (Continuous Positive Airway Pressure)
Basic Parameters
  • Tidal Volume adjustment: 0-1500ml
  • Tidal Volume: 50~1500ml, error of displayed value: 100 ml and lower than ±20 mL, others ±20 %
  • Maximum ventilation capacity per minute: ≥18L/m,
  • Oxygen Concentration: 21%-100%,±15% error allowed
  • Ventilation Conformance: ≤ 30 mL/kPa
  • IPPV range: 0~99 times/m, ±15% error allowed.
  • I/E Ratio: 4:1、3:1.、2:1.、1:1.、1:1.5、1:2.、1:2.5、1:3.、1:4, ±15% error allowed
  • SIMV: 1-20 times/m, ±15% error allowed.
  • Maximum Safety Pressure: ≤6.0kPa
  • Control Pressure: 0.3kPa ~ 4 – PEEP
  • PTR sensitivity: PEEP-1 cmH2O~PEEP—9 cmH2O adjustable, ±1 cmH2O error allowed.
  • End-inhale continuous time: 0 ~ 50% adjustable, that is 0.1s ~ 20 s.
  • PEEP: 0.1 kPa~1.0 kPa
  • flow trigger sensitivity: Level 3 and Level 8.
  • Pressure Restriction: 1~6kPa, ±20 % error allowed.
  • Sigh( deep breath): deep breath in 100 times breath, 1-8 times adjustable( after 10-100 times’
  • control breath, there will be 1 time deep breath),  the inspiration time is 1.5 times to the setup time.
  • Sustained Operation: 24 hours for main power supply, no less than 30 minutes for built-in
  • battery application only.
 

Product Detail and Usage Pictures - Advanced ventilator equipment MSLVM12

Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12Advanced ventilator equipment MSLVM12

Contact US for more videos about: Advanced ventilator equipment MSLVM12

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Other people marked this product with these tags:

Use spaces to separate tags. Use single quotes (') for phrases.

Connect Alwaysx

Connect us in Whatsapp or Facebook Messenger

Messenger

whatsapp

[profiler]
Memory usage: real: 47972352, emalloc: 46340072
Code ProfilerTimeCntEmallocRealMem