Cart0Item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

64 Clarity Multi-slice spiral CT scanner MSLCTX07-Multi-Slice Helical CT Scanner/Medical Computed Tomograpgy Scanning Machine

Quick Overview

Via the breakthrough design in precise hardware, software and imaging technologies, 64 Clarity Multi-slice spiral CT scanner MSLCTX07 can provide precise diagnosis information and early detection for small lesions.

Availability: In stock

$999.00

Details

Features of  64 Clarity Multi-slice spiral CT scanner MSLCTX07

  • AccuDose-Comprehensive low dose imaging
  • AccuScan-Enjoy ease
  • Space saving and cost saving in maintennace
  • Admir iterative reconstruction technology
  • Ahead-Head dual-energy head imaging technology
  • AccuTilt dual-mode gantry tilt technology
  • AccuOrgan-Targeted organ imaging


Specification of 64 Clarity Multi-slice spiral CT scanner MSLCTX07

  • please refer to the table below.

 

Standard Imaging Software of 64 Clarity Multi-slice spiral CT scanner MSLCTX07

  • Multi-Planar Reconstruction(MPR)
  • Curve Multi-Planar Reconstruction(CPR)
  • Surface Shaded Display(SSD)
  • Volume Rendering(VR)
  • Maximum Intensity Projection(MIP)
  • Minimum Intensity Projection(MinIP)
  • Virtual Endoscopy(VE)
  • CT angiography(CTA)
  • Tissue segmentation
  • One click bone remove
  • One click patient table remove
  • Bolus-tracking Technology
  • Spiral auto start
  • Cine display 


Client Usage Photos of 64 Clarity Multi-slice spiral CT scanner MSLCTX07

  • Please contact us for more details.

 

MSLCTX07 Specification
No. Technical feature Description
1 Gantry
1.01 Gantry type Low voltage technique slip-ring with AccuSlip-ring
1.02 Gantry driven type Strap-driven
1.03 Patient opening 70cm
1.04 Gantry tilt mode Dual-mode gantry tilt
1.05 Mechanical tilt capability ±30°
1.06 Digital tilt capability ±50°
1.07 Gantry remote-Control Provided
1.08 Detector type OptiWave rare-earth ceramic detector
1.09 Numbers of detector rows 32
1.10 Width of Z-axle detector 20mm
1.11 Detector columns of channels per row 912
1.12 Numbers of detector columns 29184
1.13 Data-transfer type RF,optical fiber communication
1.14 3D laser orientation Provided
1.15 External X-ray enable Interface for Foot-Pedal Provided
1.16 Automatic exposure control (mAModulation) Provided
1.17 Auto-voice manager Breath Graphical Display,Hold Message (Record/Playback),Breath Message(Record/Playback)
1.18 ANKE energy conservation management Provided
1.19 ECG-gating unit External type,optional
2 Scan parameter
2.01 Shortest 360 degree rotation time 0.5s
2.02 Allowed rotation times 0.5s,0.8s,1.0s,1.5s,2.0s
2.03 Slice numbers per rotation 64
2.04 Minimum slice thickness of scan 0.625mm
2.05 Minimum slice thickness of reconstruction 0.3125mm
2.06 Maximum slice thickness of scan 10mm
2.07 Nominal reconstruction slice thickness 0.3125mm,0.625mm,1.25mm,2.5mm,5.0mm,7.5mm,10mm
2.08 Speed of image reconstruction(512×512) 65 frames/s
2.09 Scan FOV 52cm
2.10 Image reconstruction matrix 512×512,1024×1024
2.10 Image reconstruction matrix 512×512,1024×1024
2.11 Image display matrix 512×512,1024×1024
2.12 Maximum continuous scan duration 120s
2.13 Maximum continuous scan length 180cm
2.14 Direction of TOPO Front-back,Left-right
2.15 Max. length of TOPO 180cm
2.16 Range of pitch 0.5~1.5
2.17 Scan mode Scout scan, Axial scan, Helical scan,Cine scan
3 HVPS and Tube
3.01 Maximum continuous output of HVgenerator 50kW
3.02 Tube kV selections 80kV,100 kV,120 kV,140 kV
3.03 Tube mA range 10~420mA
3.04 Tube anode heat capacity 5.0MHU
3.05 Heat dissipation rate 815kHU/min
3.06 Type of cooling Oil cooling + Air cooling
3.07 Tube focus Large:1.1mm×1.2mm;Small:0.6mm×1.2mm
3.08 Dynamic flying focal spot technique Provided
4 Patient table
4.01 Maximum horizontal-movable range 1850mm
4.02 Table horizontal-scannable range 1800mm
4.03 Table horizontal-position repeatability ±0.25mm
4.05 Maximum vertical-movable range 500mm
4.06 Maximum speed of vertical movement 20mm/s
4.07 Maximum speed of horizontal movement 150mm/s
4.08 Maximum patient weight 205kg
4.09 Foot pedal of patient table control Provided
5 Image Quality
5.01 High contrast resolution 21lp/cm@0%MTF
5.02 Low contrast resolution 2.0mm@0.30%
5.03 Isotropic imaging resolution 0.3125mm
5.04 Range of CT numbers -32767~32768
5.05 Image noise ≤0.25@28mGy
6 Computer subsystem
6.01 CPU 3.5GHz
6.02 Memory 64GB
6.03 Storage of hard-disk 1Tx2
6.04 Monitor 24’’ LCD Monitor
6.05 Resolution of monitor 1920×1200
6.06 Image-data external storage type CD/DVD/USB
6.07 Time of image reconstruction(512×512) 15.4ms/frame
6.08 DICOM 3.0 interface Provided
6.09 Printer DICOM 3.0 interface Provided
6.10 Auto filming Provided
6.11 Worklist function Provided
7 Advanced application
7.01 Multi-Planar Reconstruction(MPR) Provided
7.02 Curve Multi-Planar Reconstruction(CPR) Provided
7.03 Surface Shaded Display(SSD) Provided
7.04 Volume Rendering(VR) Provided
7.05 Maximum Intensity Projection(MIP) Provided
7.06 Minimum Intensity Projection(MinIP) Provided
7.07 Virtual Endoscopy(VE) Provided
7.08 CT angiography(CTA) Provided
7.09 Tissue segmentation Provided
7.10 One click bone remove Provided
7.11 One click patient table remove Provided
7.12 Bolus-tracking Technology Provided
7.13 Spiral auto start Provided
7.14 Cine display Provided
7.15 AbastTM bone artifact suppression technology Provided
7.16 AmastTM metal artifact suppression technology Provided
7.17 Admir3D full-domain iterative reconstruction Provided
7.18 Low-dose pediatric scan technology Provided
7.19 Low-dose lung scan technology Provided
7.20 AccuHead grey-white matter enhanced technology Provided
7.21 AccuLung high resolution scan technology Provided
7.22 AccuOtica inner-ear high resolution scan technology Provided
7.23 AccuBody high resolution scan technology Provided
7.24 AccuBone high resolution scan technology Provided
7.25 Ahead head dual-energy CT scan Provided
7.26 CT perfusion imaging Optional
7.27 Vessel measurable analysis Optional
7.28 Aheart cardiac scan in spiral mode Optional
7.29 ECG gating Optional
7.30 Low-dose cardiac scan technique Optional