Multi-functional operation microscope MSL20P

Multi-functional operation microscope MSL20P
$9,999.00

Availability: In stock

Model No:MSL20P Brand:Medsinglong Service:Medsinglong after-sales support. Contact us: Cindy@medmsl.com Keywords:ophthalmic instruments
OR
Description

Details

Multi-functional operation microscope MSL20P

ophthalmic microscope

Operation Microscope MSL20P is a simple surgical microscope, the body compact and lightweight, with a high degree of flexibility to meet the requirements of a variety of operations.
Features
  1, the body is compact and lightweight, with a high degree of flexibility
  2, Microscope 3 files zoom
  3, are equipped with a spring balance system, the operation microscope can move up and down freely
  4, all the lenses using multilayer coating, mold, anti-reflection technology, enhance environmental adaptability
  5, optional with different objectives and other components, but also for ENT, surgery, gynecology
 
Operation Microscope MSL20P Technical Parameters
Eyepiece magnification 12.5 × degree of visual adjustment ± 5 D Interpupillary distance adjustment range 50 mm ~ 70 mm Objective focal length 200 mm Working distance 190 mm Magnification 6X, 10X, 16X Lighting source 12 V / 100 W, cold reflective Medical halogen lamp illumination Type 6 ° cold light Coaxial illumination Coaxial illumination Surface illumination ≥10000 Lx Arm extension radius 860 mm Vertical adjustment range (ground to large objective) 850 mm ~ 1100 mm 10%, 50Hz / 60Hz? Voltage AC 220V / 110V Power 120 VA fuse AC 250V T1.25A, AC 125V T2.5A

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *
PDF Download
test content
FAQ

1. How long is the warranty?
2 years.

2. Can I choose other language?
It depends. Most machines have multiple language.

3. What certificate do you have?
Generally, most machine have CE, ISO, FSC. Some have FDA.

4. How long is the delivery?
About 4 days

5. How can I pay?
Paypal, Western Union, T/T, L/C, Trade Assurance, Money Gram etc. are accepted.

1. Can the medical incinerator burn dead body?
No, It is a non-hazardous treatment device commonly used in medical waste, such as blood cotton, needles, and disposable syringes

2. Can a medical incinerator use gasoline?
No, only diesel or natural gas liquefied gas.

What type of gas does the body cabinet compressor use?
Secop's compressors use R134a refrigerant. The refrigerant is universal and easy to buy. The refrigerant used in domestic compressors is r12, which is easy to purchase in the domestic market.

4. Does the body cabinet need to be installed before using?
No need to install. Plug it in directly. But if it is shipped by air, the refrigerant needs to be pumped out and refilled before use.

5. Is there an analysis segment for the human body analyzers MSLCA01, MSLCA02, MSLCA03, MSLCA04?
The MSLCA01 Body Analyzer does not have this function, MSLCA02, MSLCA03, MSLCA04 have the function of segmental fat, segmental moisture analysis, edema coefficient analysis, detailed body water analysis, intracellular water, extracellular water, and body water status.

6. Can the body analyzer be OEM?
It is possible when it reaches a certain amount. At present, we are all shipping from neutral machines.

7. What languages ​​does the body analyzer support?
MSLCA01 supports French, Italian, German, Portuguese, Spanish, Russian, English, Simplified Chinese, and Traditional Chinese. MSLCA02, MSLCA03, MSLCA04 support German, English, Simplified Chinese, Traditional Chinese. Lhe language needs to be confirmed in advance.

8. Can an endoscope camera connect to a monitor?
Yes, you can choose different size: 15 inches, 21 inches, 24 inches and 26 inches.

9. How often does one need to change oil in vacuum pump?

The vacuum pump oil is changed once every six months, and the pump oil is changed for 200 hours according to the frequency of use. If the catch water is overloaded, there will be a small amount of water to the vacuum pump part and then the cold trap, so the pump oil must be changed.

10. How high the degrees can the MSLFV02 refrigerator do?
Cold trap -40 degrees, plate temperature -35 degrees. This model is used for food and vegetables.

11. Can endoscopes add an extra camera?
Yes, we generally do not advise customers to purchase two cameras because the camera is the most important component of the entire device, so the price is relatively high. Of course, if customers want to buy, it is ok.

Relevant articles
test content
Inquire Now

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.