100ma new hospital x ray machine MSLCX21

100ma new hospital x ray machine MSLCX21
$9,999.00

Availability: In stock

Model No:MSLCX21 Brand:Medsinglong Service:Medsinglong after-sales support. Contact us: Cindy@medmsl.com Keywords:new x ray machines
OR
Description

Details

1.Single table and single tube 
2.conventional stomach examinations 
3.ideal x-ray diagnostic unit 

 

100ma new hospital x ray machine-MSLCX21

 

Application

 

Fluoroscopy,Digestive track spot film radiography,General radiography,

Filter-ray device radiography

Unit Configuration

Control,HT generator unit,Ht cable,X-ray tube unit,Diagnostic table,Column

 

 new x ray machines

hospital x ray machine

 

 

MAIN CHARACTERIDTICS

 

1.Single table and single tube

2.Design according to the electric mechanism of middle-size machine ,The function is reasonable

3.The high-tension system is of split structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation

4.Supply voltage (V),roentgenoscopy , radiography (kv) and stepless adjust able

5.Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output

6.Equipped with the capacity limitation and portection circuit and Kv mA S interlock limitation and protection

7.Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly,

8.Diagmafic table is of electric back rotation and is equipped with vibrating filter-ray device

9.The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy

10.The column post hast has the bottom track only, which is easy while installation

 

MAIN TECHNICAL INDEXES

 

ITEM

CONTENTS

MSLCX21:INDEX

Upright post(column)

Moving longitudinally(along the bottom track)

1500mm

landscape orientation movement

360mm

Moving up and down

720-1720mm(from focus to ground)

Supply power

Voltage

220V/380Vsingle phase

Frequency

50Hz±0.5Hz

Capacity

10KVA

Intemal resistance

380v:2Ω,220V:0.6Ω

Max DC output voltage

90KV

Max DC output current

100mA

Fluoroscopy

Voltage

50-90KV

current

≤5mA

Radiograph

Voltage

50-90KV

current

Small focus 15mm and big focus30/60/100mA four grades together

spot film

100mA(fixed)

time

0.04-6.3s,24grades together

High-voltage generator

Capacity

7KVA

X-Ray tube

Model

XD4-2.9/100

Focus

Small focus 1.8mm big focus4.3mm

Diagnostic table

rotary angle

+90°~0~-5°

specification of spot film (stomach and intestines photography)

128×179mm(5”×7”)

205×254mm(8”×10”)

254×305mm(10”×12”)

 

100ma new hospital x ray machine-MSLCX21

Focus of X-Ray tube

Radiograph mA

Max Radiograph KV

Max exposure time allow

Small focus

15mA

90KV

6.3S

Large focus

30mA

90KV

6.3S

60mA

90KV

6.3S

100mA

85KV

2.5S

 

 

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *
PDF Download
test content
FAQ

1. How long is the warranty?
2 years.

2. Can I choose other language?
It depends. Most machines have multiple language.

3. What certificate do you have?
Generally, most machine have CE, ISO, FSC. Some have FDA.

4. How long is the delivery?
About 4 days

5. How can I pay?
Paypal, Western Union, T/T, L/C, Trade Assurance, Money Gram etc. are accepted.

1. Can the medical incinerator burn dead body?
No, It is a non-hazardous treatment device commonly used in medical waste, such as blood cotton, needles, and disposable syringes

2. Can a medical incinerator use gasoline?
No, only diesel or natural gas liquefied gas.

What type of gas does the body cabinet compressor use?
Secop's compressors use R134a refrigerant. The refrigerant is universal and easy to buy. The refrigerant used in domestic compressors is r12, which is easy to purchase in the domestic market.

4. Does the body cabinet need to be installed before using?
No need to install. Plug it in directly. But if it is shipped by air, the refrigerant needs to be pumped out and refilled before use.

5. Is there an analysis segment for the human body analyzers MSLCA01, MSLCA02, MSLCA03, MSLCA04?
The MSLCA01 Body Analyzer does not have this function, MSLCA02, MSLCA03, MSLCA04 have the function of segmental fat, segmental moisture analysis, edema coefficient analysis, detailed body water analysis, intracellular water, extracellular water, and body water status.

6. Can the body analyzer be OEM?
It is possible when it reaches a certain amount. At present, we are all shipping from neutral machines.

7. What languages ​​does the body analyzer support?
MSLCA01 supports French, Italian, German, Portuguese, Spanish, Russian, English, Simplified Chinese, and Traditional Chinese. MSLCA02, MSLCA03, MSLCA04 support German, English, Simplified Chinese, Traditional Chinese. Lhe language needs to be confirmed in advance.

8. Can an endoscope camera connect to a monitor?
Yes, you can choose different size: 15 inches, 21 inches, 24 inches and 26 inches.

9. How often does one need to change oil in vacuum pump?

The vacuum pump oil is changed once every six months, and the pump oil is changed for 200 hours according to the frequency of use. If the catch water is overloaded, there will be a small amount of water to the vacuum pump part and then the cold trap, so the pump oil must be changed.

10. How high the degrees can the MSLFV02 refrigerator do?
Cold trap -40 degrees, plate temperature -35 degrees. This model is used for food and vegetables.

11. Can endoscopes add an extra camera?
Yes, we generally do not advise customers to purchase two cameras because the camera is the most important component of the entire device, so the price is relatively high. Of course, if customers want to buy, it is ok.

Relevant articles
test content
Inquire Now

Contact Information

Contact Information

  • *
  • *
  • *
  • *
  • *
  • *

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.